3
Installa
tion
C o n n e c t i n g t h e M a i n P o w e r
CAUTION:
Always disconnect and lock out the main power sources before making electrical
connections. Electrical connections should be made only by qualified personnel.
1
Open the dryer’s electrical enclosure.
Turn the disconnect dial on the dryer door to the
Off or “O” position. Lock out the main power.
See Introduction: How to Use the Lockout
Device for complete lock out information.
Turn the captive screw, and swing the door
open.
2
Insert the main power wire
through the knockout in the side of the enclosure. Secure
the wire with an appropriate strain relief.
IMPORTANT:
Always refer to the
wiring diagrams that came with your
dryer before making electrical con-
nections.
3
Connect the power wires
to the three terminals at the top of the power disconnect holder.
4
Connect the ground wire
to the ground lug as shown in the photo.
0
NOTE:
Models D600-5000
configured with process
heat and a Heater Pack at
the hopper will require
conduit from the control
panel to the Heater Pack
.
See the Appendix, in this
User Guide for more in-
formation about proper
conduit and cable size for
your application.
OFF
O
ON
I
I n s t a l l a t i o n l
3 - 7
0
NOTE:
Wiring between
process air heater, Heater
Pack, and dryer where con-
trol for this heater is lo-
cated is not included.
Maximum working distance
is 100 feet {30 meters}.
Consult Conair or a quali-
fied electrician to deter-
mine gauge of wire
required for distance.
Summary of Contents for Carousel Plus D Series
Page 6: ...iv l Table of Contents...
Page 20: ...2 8 l Description...
Page 40: ...3 8 l Installation...
Page 54: ...4 14 l Operation Control Function Flow Charts From the Login Logout screen Home Login Screen 3...
Page 90: ...4 50 l Operation...
Page 112: ...5 16 l Maintenance...
Page 208: ...C 46 l Appendix...