S e t t i n g U p Yo u r D M : T h e B a s i c s - A l a r m
L o c a t i o n ( A d v a n c e d )
( c o n t i n u e d )
The DM also automatically sets the Alarm Band.
(Establishes the
temperature range
through
which the alarm can be set.)
NOTE:
Process temperatures below the alarm band are assumed
to be insufficient to dry the material.
✐
The Alarm Setpoint is preset at band midpoint.
NOTE:
If the sensed temperature falls below the Alarm
Setpoint for a longer period than the Delay Time (default is
five minutes), the alarm will trigger an alarm message on the
control.
✐
(Can be changed by the operator to suit the process)
NOTE:
From a cold start: If, after a preset time period, the
temperature read at the selected alarm RTD does not reach
the Alarm Setpoint, DM triggers “Temperature Not Met”
alarm.
✐