P r e v e n t a t i v e m a i n t e n a n c e s c h e d u l e
No specific maintenance schedule is required for the Drying Monitor since there are no
moving parts. All components of the system are electrical in nature, but like any compo-
nent in a factory, can be prone to unforeseen breakage.
In the event of breakage, replace the component(s). Do not attempt repair.
• When material is changed.
Since a key component of the DM is the
temperature probe(s) and they are exposed to your material and elevated
temperatures, they should be checked whenever their host drying hopper is drained,
cleaned, etc. No specific preventative maintenance is required beyond wiping down
and examining for damage whenever the hopper is empty, cool and available for
inspection. In the event of visible damage or non-operation, replace the probe. Do
not attempt repair.
In addition, the coupling assembly that holds the probe in place should be closely exam-
ined from the top of the hopper and inside the hopper to be sure it is intact and has not
been damaged or become loose as a result of use in the hopper.
• Monthly, or as often as needed
r
Check that the cables and junction boxes associated with the DM.
Make sure all cables are intact, undamaged, out of harm’s way, etc.
❒
Correct the mounting integrity of junction boxes as required and re-route the
ModBus cables to avoid high amperage electrical lines and/or moving, hot or
sharp objects.
C - 4 2
l A p p e n d i x
Summary of Contents for Carousel Plus D Series
Page 6: ...iv l Table of Contents...
Page 20: ...2 8 l Description...
Page 40: ...3 8 l Installation...
Page 54: ...4 14 l Operation Control Function Flow Charts From the Login Logout screen Home Login Screen 3...
Page 90: ...4 50 l Operation...
Page 112: ...5 16 l Maintenance...
Page 208: ...C 46 l Appendix...