Recommended Water Flow Rates
Dryer Model
gal./min. {liters/min.}
600 15 {56.8}
800 15 {56.8}
1000 20 {75.7}
1300 25 {94.6}
1600 25 {94.6}
2000 25 {94.6}
2400 25 {94.6}
3200 30 {113.6}
4000 30 {113.6}
5000 30 {113.6}
C o n n e c t i n g t h e A f t e r c o o l e r a n d
O p t i o n a l P r e c o o l e r
( D 6 0 0 - 1 0 0 0 )
The aftercooler and/or optional precooler require a source of city, tower, or chiller water and
a discharge or return line. You can use water at temperatures of 45 to 85°F {7 to 29°C}. The
water flow should be at least 3 gal/min {11.4 liters/min}.
1
Connect the water supply line to
the aftercooler or precooler inlet.
If a manual shut off valve is used,
it should be mounted on the inlet
line. Conair recommends that both the
supply and return water lines have a shut
off valve.
2
Connect the water discharge or
return line to the aftercooler or
precooler outlet.
IMPORTANT:
Turn the water off when the dryer is not in use to prevent condensation.
Aftercooler Inlet
Aftercooler Outlet
IMPORTANT:
Make the
water supply and discharge
/ return connections with
flexible hoses at least 24
in. (61 cm) long. This al-
lows you to easily remove
the aftercooler assembly
for cleaning.
2
TIP:
If an optional flow
control is also being in-
stalled with the aftercooler,
the manual shut off valve
should be installed on the
inlet line for the flow con-
trol.
NOTE:
Models D600-1000
dryer aftercooler and dry
air delivery configuration
shown.
Location on
larger models are differ-
ent. Refer to the labeling
on your dryer.
0
Summary of Contents for Carousel Plus D Series
Page 6: ...iv l Table of Contents...
Page 20: ...2 8 l Description...
Page 40: ...3 8 l Installation...
Page 54: ...4 14 l Operation Control Function Flow Charts From the Login Logout screen Home Login Screen 3...
Page 90: ...4 50 l Operation...
Page 112: ...5 16 l Maintenance...
Page 208: ...C 46 l Appendix...