background image

TrueSTEAM

 

HM512, HM509, and HM506

TROUBLESHOOTING AND 

PARTS REPLACEMENT GUIDE

1

SOLENOID VALVE REPLACEMENT

CAUTION:

 Ensure outside of tank 

is cool before removing to prevent 
possible injury.

1. 

Ensure the TrueSTEAM is empty, and unplug.

2. 

Shut off and disconnect the water line from the 
bottom of the unit.

3. 

Unlock the red lever and disengage the tank from the 
valve assembly and remove tank.

4. 

Remove TrueSTEAM from the mounting 
bracket.

5. 

Remove the cover with a flathead or Torx 
screwdriver.

6. 

Disconnect the valve wire plug from the circuit 
board.

7. 

Using a flathead screwdriver, disengage the frame’s 
backplate at the four locations.

8. 

Slide the valve out of the back of the frame, and ease 
the wiring out of the TrueSTEAM frame.

9. 

Reassemble with the new solenoid valve, following 
steps 2–8 in reverse order.

IN-LINE WATER FILTER

1. 

Turn off water supply at the source (i.e. saddle 
valve)

2. 

Push in on the filter’s compression snap-lock fittings 
where the 1/4-in. water line connects.

3. 

Pull out the water line as you are pushing in the snap-
locks.

4. 

Install the new water filter, ensuring directional water 
flow is accurate per the filter label, by inserting the 
water lines on either end of the filter.

5. 

Initiate a call for humidity by turning the humidistat 
on.

6. 

Check the filter after 5 minutes of humidifier operation 
to ensure no water leakage.

WATER TANK

1. 

Press and hold the EMPTY button for 3 seconds.

2. 

Water will drain from the tank and the CLEAN TANK 
light will blink as it drains.

3. 

When the CLEAN TANK is on solid, the tank is 
empty.

4. 

Turn the water valve arm to the UNLOCK position. 
Grip the solenoid toggle valve and slide it back to 
disengage.

5. 

Hold bottom of the tank while pressing down the 
safety release button on the cover and slide the handle 
forward.

6. 

The sediment screen is on the inside of the tank at the 
bottom. Push the release button away from the tank 
wall to disengage the screen.

7. 

Pull out and clean or replace the screen.

8. 

Clean tank and reattach.

WATER SENSOR ASSEMBLY

1. 

Unplug the TrueSTEAM.

2. 

Remove the cover with a flathead or Torx 
screwdriver.

3. 

Disconnect the water sensor wire from the electric 
circuit board.

4. 

Remove the Torx screw holding down the water sensor 
assembly.

5. 

Lift the metal hinge and remove the sensor assembly 

,

 .

6. 

Replace with the new sensor assembly and connect the 
new wires to the assembly and the circuit board.

7. 

Reattach the cover.

8. 

Plug in the TrueSTEAM.

M28182

A

B

REPLACEMENT PARTS

Part

Part Number

Fig. 

Ref 

10-foot Remote Hose and 

Nozzle Kit

50024917-001

1

20-foot Remote Hose and 

Nozzle Kit

50024917-002

1

Cover

50028004-001

2

Duct Nozzle

50028003-001

3

Remote Nozzles

50028001-001

4

Mounting Bracket

50020012-001

5

Solenoid Valve

50027997-001

6

In-Line Water Filter

50028044-001

7

HM512/HM509 Water 

Tank

50033181-001

8

HM506 Water Tank

50033182-001

9

Water Level Sensor 

Assembly

50027998-001

10

Saddle Valve

32001616-001

11

Back-flow Water Valve

50030142-001

12

Differential Pressure 

Switch

50027910-001

13

M28180A

1

2

3

4

5

6

7

8

9

10

11

12

13

69-2144

Summary of Contents for Honeywell Home TrueSTEAM HM512

Page 1: ...ter will drain from the tank and the CLEAN TANK light will blink as it drains 3 When the CLEAN TANK is on solid the tank is empty 4 Turn the water valve arm to the UNLOCK position Grip the solenoid toggle valve and slide it back to disengage 5 Hold bottom of the tank while pressing down the safety release button on the cover and slide the handle forward 6 The sediment screen is on the inside of th...

Page 2: ...ss hold RESET button until the red Call Service light turns off If tank still fails to fill press and hold the EMPTY button for 3 seconds if unit fails to drain unplug unit and make sure water in tank is cool Follow tank cleaning instructions in the Professional Installation Guide Ensure you have a firm grip of the tank prior to releasing the tank especially if water is present Clear any excess de...

Page 3: ...old the EMPTY button for 3 seconds If unit fails to drain turn humidistat to OFF or unplug the humidifier and wait for water in tank to cool Ensure tank water is cool before proceeding Once cool follow tank cleaning steps in the Professional Installation Guide 69 2036EFS Reassemble tank and press the RESET button If fault persists replace the solenoid valve 14 Heater failed to boil water Press and...

Page 4: ...2 69 2144 05 M S Rev 04 20 Printed in United States www resideo com 2020 Resideo Technologies Inc All rights reserved The Honeywell Home trademark is used under license from Honeywell International Inc This product is manufactured by Resideo Technologies Inc and its affiliates 69 2144 05 ...

Reviews: