68 - Configuration Pages
RocketLinx MP1204-XT User Guide
: 2000644 Rev. A
Security | Switch | SNMP | Views
Security | Switch | SNMP | Views
Use this page to configure the SNMPv3 view table. The entry index keys are
View Name
and
OID Subtree.
Item
Configuration | Security | Switch | SNMP | Views
Delete
Check to delete the entry. It is deleted during the next save.
View Name
A string identifying the view name that this entry should belong to. The allowed
string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126.
View Type
Indicates the view type that this entry should belong to. Possible view types are:
•
included
: An optional flag to indicate that this view subtree should be included.
•
excluded
: An optional flag to indicate that this view subtree should be excluded.
In general, if a view entry's view type is
excluded
, there should be another view entry
existing with view type as 'included' and it's OID subtree should overstep the
excluded
view entry.
OID Subtree
The OID defining the root of the subtree to add to the named view. The allowed OID
length is 1 to 128. The allowed string content is digital number or asterisk (*).
Click to add a new user.
Summary of Contents for RocketLinx MP1204-XT
Page 28: ...28 Installing the Hardware RocketLinx MP1204 XT User Guide 2000644 Rev A System Reset ...
Page 36: ...36 Web Interface Overview RocketLinx MP1204 XT User Guide 2000644 Rev A Ending a Session ...
Page 180: ...180 Configuration Pages RocketLinx MP1204 XT User Guide 2000644 Rev A Configuration DDMI ...
Page 414: ...414 Glossary RocketLinx MP1204 XT User Guide 2000644 Rev A Y ...