46 - Configuration Pages
RocketLinx MP1204-XT User Guide
: 2000644 Rev. A
Configuration | Green Ethernet | Port Power Savings
Configuration | Green Ethernet | Port Power Savings
Use this page to configure port power savings on the MP1204-XT.
Item
Configuration | Green Ethernet| Power Savings
Port Power Savings Configuration
Optimize EEE for
The MP1204-XT can be set to optimize EEE for either the best power savings or the
least traffic latency.
Port Configuration
Port
The MP1204-XT port number of the logical port.
ActiPHY
Link down power savings enabled. ActiPHY works by lowering the power for a port
when there is no link. The port is power up for short moment in order to determine if
cable is inserted.
PerfectReach
Cable length power savings enabled. PerfectReach works by determining the cable
length and lowering the power for ports with short cables.
EEE
Controls whether EEE is enabled for the MP1204-XT port.
For maximizing power savings, the circuit is not started immediately to transmit data
ready for a port, but is instead queued until a burst of data is ready to be transmitted.
This generates some traffic latency.
If desired, it is possible to minimize the latency for specific frames, by mapping the
frames to a specific queue (done with QOS), and then marking the queue as an urgent
queue. When an urgent queue gets the data transmitted, the circuits are powered up at
once and the latency is reduced to the wakeup time.
Summary of Contents for RocketLinx MP1204-XT
Page 28: ...28 Installing the Hardware RocketLinx MP1204 XT User Guide 2000644 Rev A System Reset ...
Page 36: ...36 Web Interface Overview RocketLinx MP1204 XT User Guide 2000644 Rev A Ending a Session ...
Page 180: ...180 Configuration Pages RocketLinx MP1204 XT User Guide 2000644 Rev A Configuration DDMI ...
Page 414: ...414 Glossary RocketLinx MP1204 XT User Guide 2000644 Rev A Y ...