Configure Mode Commands
duplex
editing
firmware
flowcontrol
Description
Set duplex mode
Syntax
duplex { half | full | auto [ half | full ] }
Parameters
Name
Description
half
Forced half duplex.
full
Forced full duplex.
auto
Auto negotiation of duplex mode.
[ half | full ]
Advertise half /full duplex.
Description
Enable command line editing
Syntax
editing
Parameter
None
Description
Firmware swap and upgrade
Syntax
firmware { swap | upgrade }
Parameters
Name
Description
swap
Swap between Active and Alternate firmware image
upgrade
Firmware upgrade
Description
Enable/Disable flow control.
Syntax
flowcontrol { on | off }
Parameters
Name
Description
on
Enable flow control.
off
Disable flow control.