CRS-500 1:N Redundancy System
Revision 4
Cables and Connections
5–5
MN-CRS-500
5.2
CRS-500 Control Connections
5.2.1
Basic CRS-500 (CSU
DSU) Unit Connection
For 1:N redundancy configurations that do not require use of the optional CRS-280/280L IF
Switch Unit (ISU), use a CA-0000234 Control Cable (DB-25F to DB-25M, 8’) to connect the CSU
to the DSU. This is the basic setup for
all
redundancy applications. Otherwise, refer to the next
section to make the Unit-to-Unit cable connections between the CRS-500 CSU, DSU, and
optional CRS-280/280L ISU.
5.2.2
Optional CRS-500 (CSU
DSU
ISU) Unit Connections
Make sure the power supply is disconnected before you connect any
cables. Serious injury or death could occur if the power supply is
connected while you connect any cables.
When a Tx IF ISU is not present, the CRS-500 will mute the offline
modem(s)’ Tx IF.
When the optional Comtech EF Data CRS-280/280L ISU is required, configured in either a
70/140 MHz (Figure 5-1) or L-Band (Figure 5-2), and make all cable connections as instructed in
this chapter section.
Do these steps:
1. Connect and secure the CA-0000234 Control Cable (DB-25F to DB-25M, 8’) between the
CRS-500 CSU and the DSU:
a. DB-25M connector labeled “P2 | Switch Control” on the CSU’s CRS-530 System
Controller, to
b. DB-25F connector on the rear panel of the DSU labeled “J1 | CSU/DSU
CONTROL”.
2. Interconnect the optional ISU. Connect and secure the CA-0021666 Control Cable (DB-
9F to DB-25M) between the CRS-500 DSU and the CRS-280/280L ISU.
Summary of Contents for CRS-500
Page 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Page 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Page 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Page 219: ......
Page 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...