CRS-500 1:N Redundancy System
Revision 4
Serial Interface Operation
10–19
MN-CRS-500
Parameter
Type
Controller-to-Target
Instruction Code and Qualifier Arguments for
Command or
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Target-to-Controller
Command
Query
Response to
Command
Response to Query
(see Description of
Arguments)
Time
TIM=
TIM?
6 bytes
Command or Query.
Sets or returns the time from midnight, in the form hhmmss, where:
hh = hours, between 00 and 23,
mm = minutes, between 00 and 59, and
ss = seconds, between 00 and 59
COMMAND EXAMPLE: <0000/TIM=231259{CR} (Sets time as 23 hours, 12
minutes, 59 seconds from midnight, i.e., 11:12:49 P.M.)
TIM=
TIM?
TIM*
TIM=hhmmss
Temperature
N/A
TMP?
4 bytes
Query only.
Returns the unit’s internal temperature, in the form sxxx, where:
s = sign (positive [+] or negative [-])
xxx = temperature in degrees C.
QUERY RESPONSE EXAMPLE: >0000/TMP=+026{CR}{LF)
N/A
TMP=sxxx