CRS-500 1:N Redundancy System
Revision 4
Ethernet Interface Operation
9–16
MN-CRS-500
9.5.3
Status Pages
Select the
Monitor
or
Event Log
tab to continue.
9.5.3.1
Status | Monitor
Use this page to view
read-only
status windows for the active 1:N redundancy system.
Figure 9-8. ‘Status | Monitor’ Page
Redundancy System Status
This section monitors the CRS-500 Data Switch Unit (DSU) operating status. The “Virtual LEDs” light
GREEN to indicate normal operation. The LED will light RED to indicate fault conditions for the operating
temperature, switch operation parameters, configured redundant modem(s), and the dual power
supplies.
Status Summary
This section emulates operation of the CRS-500 Control Switch Unit (CSU) front panel LED
Groups. See Section 8.1.3 for detailed information about the front panel LED functions.