CRS-500 1:N Redundancy System
Revision 4
Checklists for Initial Start-up and Configuration
3–2
MN-CRS-500
3.2
Initial Start-up
Do these steps:
Step
Task (* User-provided equipment / ** Purchased Separately)
Chapter Ref
1
Unpack and inspect the CRS-500 components.
4
2
Install the CRS-500 components and modems** in a rack.
4
3
Connect cables between the CRS-500 Switch components (CSU, DSU, ISU).
5
4
Connect cables to/from the modems** and the CRS-500 components.
5
5
Connect IF cables* between either the CRS-500 ISU(s) or the signal splitters, and the IF
Downconverter*.
5
6
Configure modems for use in the CRS-500 1:N Redundancy system. Typical for all modems:
7
Power on the modems.
6
Verify that modems are running the modem’s most recent firmware version.
7
Enable Redundancy Mode.
7
Set IP Address (for M&C to/from the CRS-500).
7
Set Redundancy Traffic IP Address (if applicable).
7
Select Dedicated Ethernet Port (if applicable).
7
Configure PMSI (if Carrier-in-Carrier [CnC] is used).
7
7
Configure the CRS-500 CSU for 1:N Operation:
Power on the CRS-500.
6
Verify that the CRS-500 CSU is running its most current firmware version.
6
Configure the CRS-500’s “Switch Management” IP address.
8
Set Operating mode to Manual Switching mode.
8
Set IP address (for M&C to/from modems)
8
Set Redundancy Mode to 1:N.
8
Activate Traffic Modem(s).
8
Select Traffic Modem(s) to Bridge.
8
Set Holdoff (Backup and Restore) times.
8
Select Alarm Masks for Switch and/or Modems.
8
Perform Redundancy System Checkout.
7
Set Operating Mode to Auto Switching Mode.
8
Summary of Contents for CRS-500
Page 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Page 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Page 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Page 219: ......
Page 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...