CRS-500 1:N Redundancy System
Revision 4
Introduction
1–6
MN-CRS-500
1.3.1.1
CSU Front Panel Operational Features
Chapter 8. CSU FRONT PANEL OPERATION
Monitor and Control (M&C) of the complete CRS-500 system is accomplished
through the CSU. DO NOT DIRECTLY CONNECT TO A MODEM FOR REMOTE
(SERIAL OR ETHERNET) M&C.
Refer to Figure 1-3:
Feature 1A:
The VFD
is an active display showing two lines of 24 characters each. You can control the
brightness of its blue light.
Feature 1B:
The
six-button keypad array
is used for local control via menu navigation. The keys “click” to
give tactile feedback.
Features 1C
through
1E
comprise the
LED Indicators
:
•
The four LEDs in the
SWITCH STATUS
LED group (
Feature 1C
) show the operating
state of the CRS-500 1:N Redundant System.
•
The
TRAFFIC MODEM STATUS
LED group (
Feature 1D
) is comprised of 10 sets of four
status LEDs, plus the active
TRAFFIC MODEM
number. They show the operating state
of up to 10 Traffic modems.
•
The
REDUNDANT MODEM STATUS
LED group (
Feature 1E)
is comprised of two sets
of four status LEDs, plus the active
REDUNDANT MODEM
(RM) number. They show the
operating state of the active Redundant Modem.
Only RM 1 is operational at this time. RM 2 is reserved for future 2:N
functionality
.
Summary of Contents for CRS-500
Page 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Page 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Page 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...