B.3.1.1 CRS-530 “P1 | Remote Control” Connector (DB-9M)
This 9-pin Type ‘D’ male connector provides both EIA-232 and EIA-485 access to the remote
control ports of the CRS-500.
Table B-1. P1 | Remote Control Connector Pinouts
Pin # Description
Direction
1 Ground
–
6
EIA-485 Receive Data B (see Note)
In
2 EIA-232 Transmit Data
Out
7
EIA-485 Receive Data A (see Note)
In
3 EIA-232 Receive Data
In
8
EIA-485 Transmit Data B
Out
4 Reserved - do not connect to this pin
–
9
EIA-485 Transmit Data A
Out
5 Ground
–
Note: Use for 2-wire EIA-485 operation.