CDM-625 Advanced Satellite Modem
Revision 1
Remote Control
MN-0000036 (Ref MN/CDM625.IOM)
D–55
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response
to
Command
Query
(Instruction &
Qualifier)
Response to Query
BUC
DC
Current
N/A
4 bytes
Query only.
Indicates the value of the BUC DC current, in the form: xxxx,
where xxxx is between 0 and 9999, units mA.
If not available, response is 0000.
N/A BDC?
Exception
600L emulation:
ODC?
BDC=xxxx
(see description of
arguments)
BUC
Voltage
N/A
4 bytes
Query only.
Indicates the value of the BUC Voltage, in the form: xx.x, where
xx.x is between 0 and 64.0, units in volts.
N/A BDV?
Exception
600L emulation:
ODV?
BDV=xx.x
(see description of
arguments)
BUC
Output Power
Level
N/A
4 bytes
Query only.
BUC Output power Level, where xx.x is the value in dBm.
Returns xxxx when FSK and BUC power are not enabled.
Example:
BOL=37.4
N/A BOL?
Exception
600L emulation:
OOL?
BOL=xx.x
(see description of
arguments)
BUC
Temperature
N/A
4 bytes
Query only.
BUC temperature, in the form: sxxx, where
s = sign
xxx = number
Note:
This query is only valid when the FSK and BUC power are
turned On.
N/A BUT?
Exception
600L emulation:
ODT?
BUT=sxxx
(see description of
arguments)
BUC
Phase Lock
Loop
N/A
1 byte, value
of 0 or 1
Query only.
BUC phase lock loop:
0=Locked
1=Unlocked
Note:
This query is only valid when the FSK and BUC power are
turned On.
N/A BPA?
Exception
600L emulation:
OLL?
BPA=x
(see description of
arguments)
BUC
Software
Version
N/A
2 bytes
Query only.
BUC software version, where xx is between 0 and 15.
Note:
This query is only valid when the FSK and BUC power are
turned On.
N/A BSV?
Exception
600L emulation:
OSV?
BSV=xx
(see description of
arguments)