CDM-625 Advanced Satellite Modem
Revision 1
Remote Control
MN-0000036 (Ref MN/CDM625.IOM)
D.7.7 BUC Commands (L-Band Device)
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response
to
Command
Query
(Instruction &
Qualifier)
Response to Query
BUC
Power Supply
enable
BPS=
Exception
600L emulation:
ODP=
1 byte, value
of 0 or 1
Command or Query.
Power Supply control:
0=Disable the BUC DC Power Supply
1=Enable the BUC DC Power Supply
BPS=
BPS?
BPS*
BPS#
BPS?
Exception
600L emulation:
ODP?
BPS=x
(see description of
arguments)
BUC
10 MHz
Reference
BFR=
Exception
600L emulation:
ODR=
1 byte
Command or Query.
Where x is either 0(OFF) or 1(ON).
BFR=
BFR?
BFR*
BFR#
BFR?
Exception
600L emulation:
ODR?
BFR=x
(see description of
arguments)
BUC
Current
Low Limit
BCL=
Exception
600L emulation:
ODL=
4 bytes
Command or Query.
BUC Current Low Limit, a value between 0 and 4000mA, in
100mA increments.
BCL=
BCL?
BCL*
BCL#
BCL?
Exception
600L emulation:
ODL?
BCL=xxxx
(see description of
arguments)
BUC
Current
High Limit
BCH=
Exception
600L emulation:
ODH=
4 bytes
Command or Query.
BUC Current High Limit, a value between 0 and 4000mA, in
100mA increments.
BCH=
BCH?
BCH*
BCH#
BCH?
Exception
600L emulation:
ODH?
BCH=xxxx
(see description of
arguments)
BUC
Address
BAD=
Exception
600L emulation:
OAD=
1 byte, value
of 1 to 15
Command or Query.
BUC Address, in the form: xx, where xx is between 1 and 15.
Note:
This command is only valid when the FSK and BUC power
are enabled.
BAD=
BAD?
BAD*
BAD#
BAD?
Exception
600L emulation:
OAD?
BAD=xx
(see description of
arguments)
BUC
Output Power
Enable
BOE=
Exception
600L emulation:
OOP=
1 byte, value
of 0 or 1
Command or Query.
BUC Tx Carrier Output Power Enable, either 0(OFF) or 1(ON).
Note:
This command is only valid when the FSK and BUC power
are enabled.
BOE=
BOE?
BOE*
BOE#
BOE?
Exception
600L emulation:
OOP?
BOE=x
(see description of
arguments)
D–54