CDM-625 Advanced Satellite Modem
Revision 1
Remote Control
MN-0000036 (Ref MN/CDM625.IOM)
D–21
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction
& Qualifier)
Response to Query
Eb/No Alarm
Point
EBA=
4 bytes
Command or Query.
Eb/No alarm point in dB, with a range between 0.1 and 16 dB.
Resolution=0.1 dB
Example:
EBA=12.3
EBA=
EBA?
EBA*
EBA#
EBA?
EBA=xx.x
(see description of
arguments)
Rx Buffer Size RBS=
5 bytes
Command or Query.
Rx Buffer Size, 16 to 32768 bytes, in 2-byte steps, unless other
limitations apply. (See 6.3.1.5)
Example:
RBS=08192 (selects 8192 bytes)
RBS=
RBS?
RBS*
RBS#
RBS?
RBS=xxxxx
(see description of
arguments)
Rx Audio
Volume
Control
RVL=
4 bytes
Command or Query. (Audio/IDR parameters)
Rx Audio Volume control, in the form aabb, where:
aa=Rx 1 volume control in dB, values defined below.
bb=Rx 2 volume control in dB, values defined below.
Valid values: -6, -4, -2, +0, +2, +4, +6, +8
Example:
RVL= -2+4 (sets Rx 1 to -2 dB and Rx 2 to +4 dB)
RVL=
RVL?
RVL*
RVL#
RVL?
RVL=aabb
(see description of
arguments)
Receive
Terrestrial
Alarm Enable
RTE=
1 byte, 0 or 1
Command or Query. (INSERT mode parameter)
Receive Terrestrial Alarm Enable conditions, where:
0=Disables the alarm
1=Enables the alarm.
Example:
RTE=0 (selects Disable the alarm).
RTE=
RTE?
RTE*
RTE#
RTE?
RTE=x
(see description of
arguments)
Insert Type
ITY=
1 byte, value
of 0 thru 3
Command or Query. (INSERT/D&I++/QDI parameter)
Insert Type, where:
0=T1–D4
1=T1–ESF
2=E1–CCS
3=E1–CAS
ITY=
ITY?
ITY*
ITY#
ITY?
ITY=x
(see description of
arguments)
Rx Ternary
Code
RTC=
1 byte, value
of 0 thru 3
Command or Query. (G.703 parameter)
Rx Ternary Code, where:
0=AMI
1=B8ZS
2=B6ZS
3=HDB3
Example:
RTC=1 (selects B8ZS)
RTC=
RTC?
RTC*
RTC#
RTC?
RTC=x
(see description of
arguments)