D.7.4 Bulk Configuration Strings
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Drop & Insert
DNI=
51 bytes
Command or Query. (D&I only)
25 bytes of Drop information:
d= 24 channels (bytes) defining Timeslot locations
t= Drop type:
0=T1-D4, 1=T1-ESF, 2=E1-CCS, 3=E1-CAS, as DTY
25 bytes of Insert information:
i= 24 channels (bytes) defining Timeslot location
T= Insert type:
0=T1-D4, 1=T1-ESF, 2=E1-CCS, 3=E1-CAS) as ITY
Each Timeslot definition:
0= Unused
1-9 for timeslots 1–9, A=10, B=11, C=12, D=13…V=31.
z=timeslot zero
L= D&I Internal Loop
0 = OFF, 1 = ON
Example:
123456789ABC0000000000003123456789ABC00000000000031
Drop channels 1–12 using timeslots 1–12, and unused channels
13–24. Same for Insert. E1-CAS, D&I types, Internal Loop ON.
If framing is D&I and data rate is 1920 kbps and DNI Type is E1-
CCS or E1-CAS, then channels cannot be programmed (i.e.
FIXED CHANNEL MODE).The DNI? response will display all ‘x’ in
the time-slot positions.
DNI=
DNI?
DNI*
DNI#
DNI?
DNI?n
DNI=dddddddddddddd
ddddddddddtiiiiiiiiiiiiiiiiiii
iiiiiTL
(see description of
arguments)
Returns current D&I
configuration
where n = 0 to 9.
Returns the DNI
portion of 1 of 10
stored
configurations