Front Panel Operation
MN-0000036 (Ref MN/CDM625.IOM)
The menu indicates:
•
which of the two CSATs in currently online
•
Operating mode
•
Waveguide Switch status, both Tx and Rx: Ok or Ft (fault)
•
Redundancy Controller Box voltages: 5V and 12V values, to aid trouble-shooting
system problems.
The operating modes may be selected:
•
AUTO
mode – when the Online ODU faults, the switchover is done
automatically
to replace the faulty unit.
•
MANUAL
mode – if the Switch set-up is changed to
Manual
,
there will be no
automatic switchover in the event of a fault occuring.
NOTE:
If the ODU Redundancy system is in
AUTO
mode, a ‘forced switch-over’ can only
occur if the currently
OFFLINE
unit is fault-free.
5.10.7 ODU: FSK-control
Æ
(2 CSATs)
Æ
CSAT
CSAT
Configuration Monitor Alarms Info (
34
)
Use the
◄
►
arrow keys to select the menu option, then press
ENTER
.
5.10.7.1
ODU: FSK-control
Æ
(2 CSATs)
Æ
CSAT
Æ
Configuration
Configuration parameters:
Tx Rx LNA Misc
(
34
)
Use the
◄
►
arrow keys to select the parameters to configure, then press
ENTER
.
ODU: FSK-control
Æ
(2 CSATs)
Æ
CSAT
Æ
Configuration
Æ
Tx
Tx: Fq=6247.0 MHz Att=23.00 dB Amp=On
Mute=Unmuted Slope: xxx, Cal
(
34v
)
The user may edit:
•
Tx Frequency
– 3625 to 4200 MHz, in steps of 1.0 or 2.5 MHz
•
Tx attenuation
– 0 to 25, in increments of .25dB
•
Amplifier setting
–
Off
or
On
•
Mute setting – Muted
(i.e., Tx off) or
Unmuted
(i.e., Tx on)
•
Slope
–
Manual
(0.0 to 1.0, in increments of 0.1) or
Calibrated
5–65