CDM-625 Advanced Satellite Modem
Revision 1
Remote Control
MN-0000036 (Ref MN/CDM625.IOM)
D–12
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction
& Qualifier)
Response to Query
Tx Carrier
State
TXO=
1 byte, value of
0 thru 5
Command or Query.
Tx Carrier State, where:
0=OFF due to front panel or remote control command
1=ON
2=RTI (receive/transmit inhibit)
3=OFF due to ext H/W Tx Carrier- Off control *
4=OFF due to BUC or High-Stability Ref warm-up *
5= Carrier controlled by STDMA Controller *
Note: arguments indicated with a * are status-only. They are not
valid as a command, and are not indicated in MGC? response.
Example:
TXO=1 (Tx Carrier ON)
TXO=
TXO?
TXO*
TXO#
TXO?
TXO=x
(see description of
arguments)
Power Level
Mode
(was AUPC
Enable)
AUP=
1 byte, 0, 1, 2
or 3
Command or Query.
Power level mode, where:
0=MANUAL mode (AUPC disabled).
Normal power mode
1=AUPC enabled.
2=MANUAL-LOW.
Low power mode (-65 to -20dBm) - external attenuator
activated.
3=AUPC-LOW.
AUPC enabled and external attenuator activated
Example:
AUP=1
Notes:
•
EDMAC or D&I++, E1 D&I w/ccs or ESC++ framing must be
selected for the AUPC feature to be available.
•
External 20dB Attenuator is a hardware option.
AUP=
AUP?
AUP*
AUP#
AUP?
AUP=x
(see description of
arguments)