CDM-625 Advanced Satellite Modem
Revision 1
Front Panel Operation
MN-0000036 (Ref MN/CDM625.IOM)
may be viewed on the monitor screen. The equalizer is then turned on, and the Eb/No viewed on
the monitor screen to determine any improvement.
5.4.4.8
CONFIG: Rx
Æ
EbNo
Receive EbNo Alarm Point = 02.0 dB
(
34v
)
Select the digit of the Alarm Point to be edited using the
◄
►
arrow keys. Edit the value of the
digit using the
▲
▼
arrow keys, then press
ENTER
.
The permitted range is from 00.1 to 16.0 dB.
If the Rx Eb/No falls below this value and the fault is NOT masked, a receive traffic fault will be
generated.
5–21