CDM-625 Advanced Satellite Modem
Revision 1
Ethernet Management
MN-0000036 (Ref MN/CDM625.IOM)
6.3.3 SNMP Traps
The modem has the ability to send out SNMP traps when certain events occur in the modem. The
modem sends out traps when an alarm or a fault occurs in the modem. These include unit faults, TX
faults, RX faults, and ODU faults. A trap is sent both when a fault occurs and is cleared.
The modem supports both
SNMPv1
traps and
SNMPv2
notifications. Which style of traps the
modem sends can be configured by the user using the CDM625SNMPTrapVersion OID.
The following are the MIB2 v1traps/v2 notifications that the modem supports:
MIB2 SNMPv1 trap: Authentication Failure
5
MIB2 SNMPv2 notifications: Authentication Failure
1.3.6.1.6.3.1.1.5.5
The following tables are the Alarms and Faults v1 traps / v2 notifications that the modem supports.
Alarms and Faults
SNMPv1
traps:
cdm625UnitAlarmV1
6247641
cdm625TxTrafficAlarmV1
6247642
cdm625RxTrafficAlarmV1
6247643
cdm625OpenNetworkAlarmV1
6247644
cdm625BUCAlarmV1
6247645
cdm625LNBAlarmV1
6247646
Alarms and Faults
SNMPv2
notifications:
cdm625UnitAlarm
1.3.6.1.4.1.6247.34.2.0.1
cdm625TxTrafficAlarm
1.3.6.1.4.1.6247.34.2.0.2
cdm625RxTrafficAlarm
1.3.6.1.4.1.6247.34.2.0.3
cdm625OpenNetworkAlarm
1.3.6.1.4.1.6247.34.2.0.4
cdm625BUCAlarm
1.3.6.1.4.1.6247.34.2.0.5
cdm625LNBAlarm
1.3.6.1.4.1.6247.34.2.0.6
6–3