ID-Mobile Global Guide
94
Setpoint group
Engine protection
Related FW
2.6.0
Range [units]
0 .. Nominal RPM [RPM]
Default value
500
Step
1 RPM
Comm object
10139
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Binary output Ready to load is closed if RPM > MinLoadSpeed and engine is in Running state. Use this
output to enable/disable connecting of engine load. MinLoad speed is an condition to close BO Close load
when panel On/Off button is closed.
MinLoadSpeed
Setpoint group
Engine protection
Related FW
2.6.0
Range [units]
8 .. Batt >V [V]
Default value
8
Step
0.1 V
Comm object
8387
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Warning (last acceptable) level for low battery voltage.
Batt <V
Setpoint group
Engine protection
Related FW
2.6.0
Range [units]
Batt <V .. 40 V [V]
Default value
30
Step
0.1 V
Comm object
9587
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Warning level for battery overvoltage.
Batt >V