ID-Mobile Global Guide
211
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
9
Description
Value can be used as engine Running indication – see
.
Oil Press
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
77
Description
Logical Analog input for value to be displayed on Bodas display.
Oil Temp
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
68
Description
Analog Input influences directly Engine Requested RPM register when configured without ramp. In the case
of sensor fail (out of range) is Sped request = 0 for AS and 50% (=Nominal RPM) for SS configuration.
Requested RPM
Analog inputs configuration example
for ID-Mobile Starter kit to be displayed on CANtrak-1.1 and Bodas-1.3 with default software.
Analog input
Dim
Sensor
Resolution
Sensor
range
Bargr.
100%
Logical
function
1.
Oil Press
Bar
0-2400ohm
0.01
15.00
5.00
Oil Press
2.
Cool Temp
°C
0-2400ohm
1
350
120
Coolant Temp
3.
Oil Temp
°C
0-2400ohm
1
350
140
Oil Temp
4.
Fuel Level
%
0-2400ohm
1
240
100
Fuel Level