8.2 Extension modules
Following items is possible to configure in DriveConfig – Modules
Module
No
ID-Mobile
[1/1]
It is obligatory item.
Binary Inputs module
[x/8]
Use for extension modules IGS-PTM, IS-BIN16/8 and ICB.
Binary Outputs module
[x/8]
Use for extension modules IGS-PTM, IS-BIN16/8, IGL-RA15 and ICB.
Analog Inputs module
[x/4]
Use for extension modules IGS-PTM, IS-AIN and ICB.
Analog Outputs module
[x/4]
Use for extension modules IGS-PTM, I-AOUT8 and ICB.
Shared Binary inputs
[x/4]
Binary data transfer between ID-Mobile Master and Slave.
Shared Binary outputs
[x/4]
Binary data transfer between ID-Mobile Master and Slave.
Shared Analog inputs
[x/4]
Binary data transfer between ID-Mobile Master and Slave.
Shared Analog outputs
[x/4]
Binary data transfer between ID-Mobile Master and Slave.
ECU
[x/1]
Item for J1939 electronic engines support.
ICB module
[x/1]
Item for other than J1939 electronic engines support.
Virtual Binary Outputs
[x/4]
For data transfer via Modbus – e.g. separate fault indications.
PLC
[x/1]
Select this item before PLC functions configuration.