8.2.1 ID-Mobile Master – Slave concept
ID-Mobile Master:
Master module i.e. standard ID-Mobile hardware is dedicated as single unit.
ID-Mobile Slave:
Slave module can be used to increase number of I/O and PLC functions and/or transfer signals from machine
moving part just via CAN bus to reduce wiring. ID-Mobile Slave is equal to Master hardware and its function is
blocked when used as single unit - without Master.
ID-Mobile slave and master need to be discussed with WNPR if work or not and how to describe properly
When ID-Mobile Slave works as single unit:
“Sd MasterCommErr” is indicated in Alarm list and in History
All Analog inputs are indicated as ##### invalid value
All Binary inputs are indicated as # invalid value
Master and Slave can share values via “Shared Binary and Analog I/Os” via CAN2. There is one common ID-
Mobile-1.1 (or higher) firmware for both. Ordering code is ID-Mobile Slave.