ID-Mobile Global Guide
10
Engine specific, plug and play support of engines with ECU – access to all available engine values
Designed specifically for harsh environment – trouble free operation in all conditions
Built-in Event & Performance Log – easy troubleshooting and warranty claim handling
Remote monitoring support – reduced call-out costs of service engineers
Fleet management program with GPS localization of supervised machines available
1.7.2 Features
Running-hours meter, number of starts counter, fuel consumption indication
RS485 communication line with Modbus
J1939 and Modbus ECU support with Input / Output configuration
Engine measurement and control by sensors and actuators or via J1939
CAN1-bus line for extension (Slave) modules and J1939
CAN2-bus line for connection of external display
Optional internal GSM/GPRS modem and/or GPS receiver
12 Binary inputs for contacts switching to Battery– or , 4 Binary inputs with broken wire detection
8 Analog inputs configurable for industry standard sensors
8 Binary switches configurable as:
Hi-side switches 3A with detection of broken wire
Low-side switches 3A
PWM switches 3A
8 configurable analog inputs / outputs:
voltage (10VDC, 20mA, 24VBat) outputs compatible with hydraulic proportional valves
20mA, 5VDC, 24VDC, 2.5 kΩ, PT1000 inputs
8 Binary Hi-side switches with max. current 3A and detection of broken wire
4 Frequency inputs for RPM measurement
2 Impulse inputs for rotary flow meters or other cumulative measuring
Internal – configurable PLC functions: Logical functions, Comparators with delay or hysteresis, Analog
switches, Mathematical functions, Linear interpolation, Filters, PID loops with analog or binary outputs,
Counters, Timers, Delay functions
Operating temperature: –40 to +70°C
Supply voltage: 8-36 VDC continuously, 6 VDC for 1s
EMC compatibility: EN61000-6-1/2/3/4, SS4631503(PL4), IEC 255-3
Vibration resistivity: IEC 60068-2-6, 5-28Hz / ± 1,5mm, 28-150Hz/5g,
Shock test: IEC 68-2-27
Dust and water protection IP6x, IPx9