ID-Mobile Global Guide
129
Analog outputs availability
Module
Number of outputs
Note
ID-Mobile
AOUT1 to AOUT8
ECU (J1939)
4 (virtual outs)
Format depends on ECU
I-AOUT8
4× 8 Analog outputs
Analog outputs configuration
The two limits “Lo limit” and “Hi limit” can be modified in DriveConfig. “Lo limit” corresponds to low Analog output
limit i.e. 0V or 0mA output and Hi limit corresponds to full range 10V or 20mA output. Lo limit and Hi limit transfer
the full internal analog value range to Analog output range.
Following is example of transfer characteristics 0 - 100% to 0 – 20mA and 4 -20mA.
Group: Analog CU
Values are shown and titled according to configuration AIN1 – AIN11 and:
Value group
Analog CU
Related FW
2.6.0
Resolution [units]
[V]
Comm object
8213
Related applications
AMF, MRS
Description
Voltage of the battery (Power source for the controller).
Battery Volt
Value group
Analog CU
Related FW
2.6.0
Resolution [units]
[°C]
Comm object
10124
Related applications
AMF, MRS
Description
Processor temperature of the controller.
CPU Temp
Group: Binary CU