Chapter 5: Maintenance and troubleshooting
98-140012-H
Troubleshooting
130
10308
Software update
failed. Try running
the update again.
Software upload failed to
initialize, can be a sporadic
issue.
Try running the update
again.
If the problem persists,
contact your distributor.
10309
Software update
failed. Update to
the latest software
version.
The software has been rolled
back to the previous version
prior to starting the software
upload. The new image was
not validated correctly.
Try running the update
again, if the problem persists,
contact your distributor.
1030A
Software failed.
Update to the
latest software
version from Safe
Mode.
Not all subunits have been
properly verified with the
new image.
Attempt software update
procedure again,
alternatively from Safe
Mode if the problem persists.
1030B
Antenna software
failed. Update to
the latest software
version from Safe
Mode.
The antenna software could
not be verified.
Attempt software update
procedure again,
alternatively from Safe
Mode if the problem persists.
The antenna is a subunit
with relation to the software
update process, and if that
particular unit fails, this
event is raised instead of
0x1030A
1030C
Software update is
already started
Another software update
cycle is currently running.
Wait until the current
software upload has finished.
1030D
Software version is
already installed
The software image you are
trying to install is already
active on the terminal.
Update with a different
image as it is prohibited (and
nonsensical) to start a sw
update process with the
same image.
1030E
Software update
forced roll-back
Software update failed and
the terminal forced a roll-
back to the previous version.
Check that you have the
correct file for software
update and try again.
If the problem persists,
contact your distributor.
11001
Calibration error
Invalid calibration values
found.
Contact your distributor.
Event ID
(Hex)
Displayed text
Explanation
Remedy