Refrigerator operation
108
www.coachman.co.uk
O
w
ners h
andb
o
ok
2
02
2
Coachman Caravan Company Limited, Amsterdam Road, Sutton Fields Industrial Estate, Hull, HU7 0XF
Code LEDs
Fault
Type
Solution
E12
Gas valve check error
Error
Gas operation is not possible. Reset the error manually.
Contact customer service if this error occurs again.
E13
Internal communication error
Error
Gas operation not possible. Reset the refrigerator.
Reset the error manually. Contact customer service if
this error occurs again.
E50
Gas lock after 3 ignition attempts
Error
Ignition not possible. The gas cylinder is empty. Replace
the gas cylinder. Reset the error manually.
E51
Gas lock, internal error in the
power module
Error
Reset the error manually.
Contact customer service if this error occurs again.
E52
Ground contact, gas valve
Error
Reset the error manually.
Contact customer service if this error occurs again.
In autonomous gas operation:
The battery charge of the battery
packs is low.
Error
Insert new batteries.
E53
Ground contact ignition electrode
Error
Reset the error manually.
Contact customer service if this error occurs again.
Tank stop mode: Gas operation is
blocked for 15 minutes.
Warning
Wait 15 minutes or switch to another operating mode.
Recurring
beeps
Door left open
Warning
Close the door.