TROUBLESHOOTING AND ELECTRICAL SYSTEM
Test Procedures
11
986
Figure 11-27
Disconnect Charge Coil Plug
990
Figure 11-28
Disconnect Engine Kill Wire
1076
Figure 11-29
Disconnect Solenoid Coil Wire
5.
Set the multimeter to the diode test function.
6.
Connect the black (–) probe of the multimeter to the frame (ground)
7.
Connect the red (+) probe of the multimeter to the end of the 16-gauge green wire (w110).
8.
The reading should indicate an over limit (no continuity). If the diode conducts current (shows continuity) with
the meter probes connected as described, the diode has failed and must be replaced.
9.
Reverse the multimeter probes and note the reading
. The multimeter should indicate
approximately 540 mV, however, a range of 400-700 mV is acceptable.
10. If the readings obtained in the previous steps are incorrect, replace the diode.