Tightening sequence
60
P2398PM | 2022-07
Apex Tool Group
4
EN
The final speed must be lower than the standard speed.
The angle counting starts when the
Threshold Torque
is reached.
After switching off via the
Shut-Off Torque
/
Shut-Off Angle
, the torque that develops or the associated an-
gle is compared with the
Minimum/Maximum Torque
and the
Minimum/Maximum Angle
and evaluated
OK/NOK accordingly.
The following parameters can be prog rammed in the particular FastApp configuration,
see chapter 3.6
FastApps menu, page 19
.
Parameter
Description
Range of values
Abbrev.
Speed
Speed selection: In the range of the
maximum speed specified in the tool
constants, with validity at the begin-
ning of the sequence up to the thresh-
old torque (mPro mode)/Speed
threshold (FastApps mode).
Begin: With tool start
End:
Threshold Torque (mPro mode)
Speed threshold (FastApps
mode).
± Maximum speed
n (rpm)
Speed Threshold (rpm)
1
Speed when the maximum torque is
reached. Must be less than the start-
ing
Speed
sein.
FastApps-Modus
As soon as the speed threshold is
reached, the speed is reduced from
the starting speed to the final speed at
the maximum torque. With increasing
torque, the speed drops.
Begin: From the Speed Threshold
Torque
Ende: Shut-Off Torque
Pro mode
In mPro mode, the parameterization
of the controller is valid.
± Maximum speed
n2
Maximum Angle
Upper limit of attained angle.
0 ... 9 999
AngMax
(deg)
Maximum Torque
Upper limit of attained torque.
TqMax
Minimum Angle
Lower limit of attained angle.
0 ... 9 999
AngMin
(deg)
Minimum Torque
Lower limit of attained torque.
-Off Torque
TqMin
Threshold Torque
Beginning of angle counting.
TqTh
Shut-Off Torque
Valid monitoring torque during the
tightening process. If the monitoring
torque is exceeded, the drive stops
immediately.
TqP
Shut-Off Angle
0 ... 9 999
AP (deg)
1
The maximum torque is not normally reached. The torque shutoff value is less than the maximum torque.
Therefore, it is not completely regulated to the final speed.