Troubleshooting
62
P2398PM | 2022-07
Apex Tool Group
5
EN
Error message
Description
OFF1
Offset error, Transducer 1
P1M>
Torque in Phase 1 too high
P2M<
Torque in Phase 2 too low
P2M>
Torque in Phase 2 too high
P2UU
To much under- and overstep in Phase 2
P3M<
Phase 3: Torque too low
P3M>
Phase 3: Torque too high
P4M<
Phase 4: Torque too low
P4M>
Phase 4: Torque too high
PAR
Wrong parameter
PS?
Wrong parameter set
RAM
Memory error, measuring board
SA
Canceled by removal of the start signal
SeBB
No ready signal for servo
SS>
Max. number of cycles for stick-slip exceeded
SST>
Max. number of cycles for stick-slip exceeded
TDS
Shutoff by depth sensor
TMAX
Canceled by exceeding the max. time
TMS<
Angle redundancy by time below min Value
TMS>
Angle redundancy by time exceeded
TQ<
Torque too low
TQ>
Torque too high
WG1D
Error in Angle Encoder 1
WIG<
Total angle too small
WIG>
Total angle too large
ZRF
Gear defective
Error messages, software updates and data storage
Error message
Description
Measure
E1
Export script not available.
Try to export the script two to three times.
If the error message continues to occur, perform a
software update.
E2
Error during export.
Connect USB stick.
Check USB stick for errors.
E3
Error while writing the ar-
chive.
Check USB stick for errors.
E10
Software update script not
available.
Try two to three times to perform the software up-
date
If the error message continues to occur, contact a
Sales & Service Center
, see reverse
E50
Crash during software up-
date.
E99
Timeout on startup expired.
Connect USB stick.
E110
No compatible update
packages found.
Make sure there is the right
*.tma
file selected.
E121
License is invalid.
Download the license again and install it on the
tool. The
*.xml
file must not be modified.