Menus And Functions
Apex Tool Group
P2398PM | 2022-07
21
3
EN
Button
Description
For a torque shutoff, enter the shut-off torque.
For an angle shutoff, enter the shut-off angle.
Once the value has been reached, the tightening process is completed. This setting
option is the same as in the menu
Advanced Settings
.
Note
If the shut-off value is entered here in the
Configuring FastApps
menu, then the follow-
ing values are calculated automatically:
Parameter
Shut-off Torque
Shut-off Angle
Minimum Torque
-15% of the Shut-off
Torque
Threshold Torque
Maximum Torque
+15% of the Shut-off
Torque
Tool capacity
Minimum Angle
0
-10 deg of the Shut-off An-
gle
Maximum Angel
9999
+10 deg of the Shut-off An-
gle
Threshold Torque
50% of the Shut-off Torque Manual input
Final Speed
50
50
Speed Threshold
1/4 x of the Shut-off
Torque
Threshold Torque
These values can be changed manually in the
menu,
see chapter 3.6.4 Ad-
vanced Settings, page 23
.
Entering the Threshold Torque.
This button is only displayed during angle shutoff. This setting option is the same as in
the menu
Advanced Settings
.
Batch display
Enter the number of tightening positions for a FastApp.
Start Speed display.
Enter the Start Speed.
Advanced settings.
Block Angle Detection activated.
If block angle detection is enabled, a block angle of 180° is added to torque/angle
shutoff. This block angle is used at the start of rundown, to detect if screw is already
tighten or thread/screw damaged or crooked screwed -in. The angle counting starts af-
ter the block angle.
So if within that first 180° the torque exceeds the shutoff-torque (torque shutoff) or
maximum torque (angle shutoff), the rundown is aborted and the "BLOC" error is show.
Block Angle Detection disabled.