Troubleshooting
Apex Tool Group
P2398PM | 2022-07
61
5
EN
5
5.1
Error messages
Error messages for shut-off cause
Error message
Description
?S?
Abort due to other errors
Ang<
Angle too small
Ang>
Angle too large
Abbr
Abort by the controller
ANF1
Transducer 1 absent
AW<
Too few graphic values recorded for an evaluation
BLOC
Tightened on block
Erg?
Measuring board provides no result
FC<
Clamping force too low
FC>
Clamping force too great
FLT
Servo warnings
FMK
Measuring board error
FPEF
Error in Snug Point Detection
FRC<
Residual clamping force too low
FRC>
Residual clamping force too great
FSMW
Not enough rundown data
GD<
Gradient too small
GD>
Gradient too large
GEB?
Encoder error torque/angle
IP
Error output section, excessive current
IRED
Current/TQ redundant
JUM
Error due to the socket slipping off
KAL1
Calibration error, Transducer 1
COMM
Host<-->TM communication error
LEF
Bearing fault
M1<
Torque M1, threshold not reached
M1>
Torque M1 exceeded
M2<
Torque M2, threshold not reached
M2>
Torque M2 exceeded
MBO>
Torque has exceeded top evaluation torque
MBU<
Torque has fallen below bottom evaluation torque
MDSI
Safety torque exceeded
TQUE
Torque too high
TQUN
Torque too low
ME>
Press-in torque too high
MDTE>
Maximum distribution torque exceeded
NECK
Socket or nutrunner break
NOT
End due to emergency stop