Menus And Functions
Apex Tool Group
P2398PM | 2022-07
53
3
EN
Fig. 3-44: Graphics export Torque graph
The
*.svg
file contains the following values:
Column
Description
Tool Type
Tool type with which the tightening was done
Tool Serial
Serial number of the tool
Date
Date of export: Day.Month.Year
Time
Time of export: Hour:Minute:Second
App
Number of the FastApp
ID
Number of the graphic entry. The number is identical to the
GraphicID
for the ar-
chive.
Tq low [Nm]
Minimum Torque
Tq high [Nm]
Maximum Torque
Tq [Nm]
Shut-Off Torque
Ang low [deg]
Minimum Angle
Ang high [deg]
Maximum Angle
Ang [deg]
Shut-Off Angle
Target
Switch-Off value, depending on the selected tightening strategy the unit is
Nm
or
deg
.
Shutoff reason
Shut-Off reason