Menus And Functions
Apex Tool Group
P2398PM | 2022-07
15
3
EN
Display of the rundown data
Symbol
Description
Linking group/Batch display
Number of tightening positions for a Linking group.
If there is only one Linking group, then each result is evaluated.
If there is more than one Linking group, the overall result of all the tightening posi-
tions is considered.
Example: 2/3
Current tightening position: 2
Total number of tightening positions: 3
Display of the torque for the current tightening.
If an arrow pointing up appears next to the symbol, the result is too high.
If an arrow pointing down appears next to the symbol, the result is too low.
Display of the angle for the current tightening.
If an arrow pointing up appears next to the symbol, the result is too high.
If an arrow pointing down appears next to the symbol, the result is too low.
Indicates that the node number or IP address of the tool is assigned twice.
Change the node number or IP address.
3.4.2
Run screen in the FastApps mode
Fig. 3-4: Run screen in FastApps mode
Display of the FastApps
Symbol
Description
Display of the currently selected FastApp.
Up to ten FastApps can be programmed. The number on the button indicates which
FastApp is selected.
Display of the tightening strategy.
Display of the torque shutoff. The value to the right of the symbol indicates the
shut-off torque.