4-24
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter 4
ILMI Commands
upilmi
upilmi
Up ILMI—activate ILMI on a resource partition.
Use upilmi to activate interim local management interface (ILMI) for a particular resource partition on
a logical port. Before running the upilmi command for the partition, you must:
1.
Activate a line through the upln command and configure the line through cnfln
2.
Create a logical port through the addport command
3.
Add resource partitions through addrscprtn
After activating ILMI, you can configure ILMI though the cnfilmi command.
Cards on Which This Command Runs
AXSM
Syntax
upilmi <ifNum> <partId>
Syntax Description
Related Commands
cnfilmi, dspilmi
Attributes
Example
Determine whether ILMI is up on logical port 1, resource partition 1. If ILMI is down (or off), activate
it by using the upilmi command. Note the second time you run the dspilmi command, the ILMI state
appears as “on.”
M8850_NY.5.AXSME.a > dspilmi 1 1
Sig. rsrc Ilmi Sig Sig Ilmi S:Keepalive T:conPoll K:conPoll
Port Part State Vpi Vci Trap Interval Interval InactiveFactor
---- ---- ---- ---- ---- --- ------------ ---------- ----------
1 1 Off 0 16 Off 1 5 4
M8850_NY.5.AXSME.a > upilmi 1 1
Warning: connections (if any) on port could get rerouted.
Do you want to proceed (Yes/No) ? y
ifNum
Logical port number. On the AXSM, the range is 1–60.
partId
The range for partition identifier is 1–5.
Log: log
State: active, standby
Privilege: GROUP1