3-92
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter 3
Equipment and Resource Provisioning
dspportsct
Display the Class of Service Buffer parameters for SCT 3 Note the following:
•
Min-Rate and Max-Rate do not apply in the current product.
•
Excess-Priority is a scheme for distributing excess bandwidth. The lowest number is the highest
priority for a connection to receive excess bandwidth. If two or more connections have equal
priority, the excess bandwidth is equally distributed between them.
•
Explicit Rate Stamping (ERS) applies to only ABR connections.
•
Cell loss ratio (CLR) is currently hard-coded, so do not attempt to modify it through CWM.
MGX8850.9.AXSM.a > dspportsct cosb 3
+-----------------------------------------------------------------------------------+
|Service Class Template [03] : COSB Parameters
+-----------------------------------------------------------------------------------+
| COSB | MIN-RATE | MAX-RATE | MIN-PRIORITY | EXCESS-PRIORITY | ERS ENABLE | CLR |
+-----------------------------------------------------------------------------------+
| 0001 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0002 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0003 | 00000000 | 00000100 | 000 | 000 | DISABLE | 10^-10 |
| 0004 | 00000000 | 00000100 | 000 | 001 | DISABLE | 10^-08 |
| 0005 | 00000000 | 00000100 | 000 | 001 | DISABLE | 10^-06 |
| 0006 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0007 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0008 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0009 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0010 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0011 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0012 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0013 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0014 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0015 | 00000000 | 00000100 | 000 | 002 | DISABLE | 10^-06 |
| 0016 | 00000000 | 00000100 | 000 | 000 | DISABLE | 10^-06 |
+-----------------------------------------------------------------------------------+
Display VC thresholds for SCT 3. Note the following:
The Scaling COSB value applies to congestion in a Class of Service Buffer: if a buffer becomes
congested, this value determines how quickly the node throttles back the rate that cells enter the buffer.
The Scaling Log-If is a scaling factor that applies to congestion on a port: when the port is congested,
this factor determines the rate at which traffic is throttled back.
MGX8850.9.AXSM.a > dspportsct vcThr 3
+---------------------------------------------------------------------------------------------------------+
Service Class Template [3] : VC Threshold Parameters
+---------------------------------------------------------------------------------------------------------+
| SERV-TYPE | VC THRESH | PACKET | MAX_CELL | EFCI | CLP_HI | EPD0 | CLP_LO | SCALING | SCALING |
| | TBL IDX | MODE | THRESH | | | | EPD1 | COSB | Log-If |
+---------------------------------------------------------------------------------------------------------+
| VSI-SIG | 034 | DSB | 0000005000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000002 | 0000002 |
| CBR.1 | 035 | DSB | 0000002500 | 1000000 | 0800000 | 0600000 | 0800000 | 0000001 | 0000001 |
| VBR-RT.1 | 036 | DSB | 0000005000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000002 | 0000002 |
| VBR-RT.2 | 037 | DSB | 0000005000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000002 | 0000002 |
| VBR-RT.3 | 038 | DSB | 0000005000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000002 | 0000002 |
| VBR-nRT.1 | 039 | DSB | 0000025000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000002 | 0000002 |
| VBR-nRT.2 | 040 | DSB | 0000025000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000002 | 0000002 |
| VBR-nRT.3 | 041 | DSB | 0000025000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000002 | 0000002 |
| UBR.1 | 042 | DSB | 0000050000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000004 | 0000004 |
| UBR.2 | 043 | DSB | 0000050000 | 1000000 | 0800000 | 0600000 | 0800000 | 0000004 | 0000004 |
| ABR | 044 | DSB | 0000050000 | 0200000 | 0800000 | 0600000 | 0800000 | 0000003 | 0000003 |
| CBR.2 | 045 | DSB | 0000002500 | 1000000 | 0800000 | 0600000 | 0800000 | 0000001 | 0000001 |
| CBR.3 | 046 | DSB | 0000002500 | 1000000 | 0800000 | 0600000 | 0800000 | 0000001 | 0000001 |
+---------------------------------------------------------------------------------------------------------+