CAUTION
The unit is designed to take power through 24 Vdc
Power-
over-Ethernet
only, and does not have a dedicated power port.
A 24 Vdc PoE injector is included with the unit. Do not connect
any 48 Vdc PoE injector, and do not attempt to connect any
other source of electrical power to the unit.
Connect the included 24 Vdc PoE injector to the unit by doing the
following steps:
1.
Only use a patch Ethernet cable to connect the PoE injector and
the unit.
2.
Insert the RJ45 connector leading from the PoE injector into the
Ethernet port labelled
LAN1/POE
.
5.1.5. Rebooting the firmware and resetting the unit to factory
defaults
The Cisco FM1200 Volo hardware can be rebooted and reset to factory
default condition using the procedures in this section.
IMPORTANT
The following procedure shows how to do a 'hard' (device
firmware) reboot. To do a 'soft' (device software) reboot, refer
to
“Resetting the unit to factory defaults” (page 138)
.
To do a 'hard' (device firmware) reboot under emergency conditions (for
example, if the unit malfunctions), do the steps in the following sub-
section.
Device firmware reboot
1.
Remove the bottom cover from the main unit enclosure as shown
in
“Connecting LAN cables to the unit” (page 39)
.
2.
Insert a long tool with a thin shaft, such as a paper clip or a thin
screwdriver, into the
RESET
button port until the tool touches the
bottom (
Hardware installation