Cisco TelePresence System TX9000 and TX9200 Assembly, Use & Care, and Field-Replaceable Unit Guide
OL-27038-01
Chapter 15 First-Time Setup
Powering on the System and Enabling the Cisco TelePresence Administration Software GUI
Step 1
Load the Cisco TelePresence Administration Software image on the Unified CM server.
Note
The Cisco TelePresence System TX9000 and TX9200 systems require a minimum version of CTS
administration software 1.9.0 to run. If your Unified CM is already running the required minimum
software, you can skip this step.
For more information, refer to the following sections in the
Cisco Telepresence Touch 12 Installation
•
If you are upgrading from a software version that prior to 1.7.4, follow the steps in the
the CTS Software for Systems That Are Running Cisco TelePresence Software Versions Prior to
1.7.4”
section.
•
If you are upgrading from a software version that is 1.7.4 or later, follow the steps in the
the CTS Software for Systems That Are Running Cisco TelePresence Software Versions 1.7.4 and
Above”
section.
Step 2
Register your system as a device in Unified CM. For more information, refer to the
section in the
Cisco Unified Communications Manager Configuration
Guide for the Cisco TelePresence System
Step 3
Add the TFTP server for your Unified CM server to your system using the Cisco TelePresence
Administration Software GUI. For more formation, refer to the
of the
Cisco TelePresence System Administration Guide
for your software release.
For more information about configuring Unified CM with your Cisco TelePresence device, refer to the
Cisco Unified Communications Manager Configuration Guide for the Cisco TelePresence System
Powering on the System and Enabling the Cisco TelePresence
Administration Software GUI
Note
The Cisco TelePresence System TX9000 and TX9200 systems require a minimum version of CTS
administration software 1.9.0 to run.
To load the CTS Administration Software, complete the following steps:
Step 1
Open the left and right facade panels by pulling them out from the top.
Note
These panels pivot outward and are directly below the left and right displays.
Step 2
Power on the four PDUs in the display assembly, two on each side.
Note
Power on all codecs within 30 seconds to avoid power on detection failure.