Cisco TelePresence System TX9000 and TX9200 Assembly, Use & Care, and Field-Replaceable Unit Guide
OL-27038-01
Chapter 13 Building the Second Row Table For a 14- and 10-Seat TX9200 System
Assembling a 4-Seat Second Row For a 10-Seat TX9200 System
Step 14
Connect the power cables, and route and connect the power and Ethernet cables, by completing the
following steps:
a.
Attach jumper cables to the second row PDUs and route the cables to the right (the side nearest table
leg 800-37778-xx). These cables are shown in blue in
If required, use two jumper cables to connect the power outlets for table leg 800-37776-xx. You
connect a total of six jumper cables.
b.
Route the cables for the second row table as shown in
.
•
Place the power cables in the bottom row of the cable trays.
•
Place the Ethernet cables in the middle row of the cable trays.
c.
Neatly bundle any excess cable and secure the cables with Velcro straps (callout 1).
Use Velcro straps (callout 1) to cleanly route the cables.
d.
Attach the table leg side panel assemblies (callouts 2, 3, 5, and 6).
e.
Level the table assembly using a laser level and the diamond marks on the sides of the legs as a
reference point.
For additional cabling information, see
Chapter 10, “Connecting and Routing the Cables.”
Note
shows a second row with six sections; however, this assembly step is the same for either a
10-, 14-, or 18-seat system.
Key
Part Description
Part Number
Qty
Ctn
Notes
1
Table leg side panel assembly, second
row left
700-37182-xx
Kit # 800-37777-xx
Subkit # 69-2314-xx
1
51
2
Table leg side panel assembly, second
row right
700-37183-xx
Kit # 800-37777-xx
Subkit # 69-2314-xx
1
51
3
Table leg side panel assembly, second
row far right
700-37722-xx
Kit # 800-37778-xx
Subkit # 69-2314-xx
1
51
4
Table leg side panel assembly, second
row far left
700-37721-xx
Kit # 800-37776-xx
Subkit # 69-2314-xx
1
51
5
Velcro straps
52-0499-xx
Kit # 69-2403-xx
Subkit # 53-3789-xx
70
6
Not shown in
6
Power jumper cables
37-0833-xx
Kit # 69-2351-xx
6
48