2-7
Cisco TelePresence System TX9000 and TX9200 Assembly, Use & Care, and Field-Replaceable Unit Guide
OL-27038-01
Chapter 2 Room Requirements for the TX9000 and TX9200 Systems
Room Dimensions for the TX9000 and TX9200
Figure 2-2
TX9200 Minimum Room Dimensions
Table 2-6
Callouts for
Callout
Description
1
The minimum room width is 31’ (9450 mm). Rooms can be wider.
Note
The overall width of the second row table is 7.694 meters (25’ 3”)
2
The minimum room depth is 21’ 5” (6530 mm) for systems that use a wall-mounted reflector wall,
22’ 1” (6730 mm) systems that use a free-standing reflector wall. Rooms can be deeper.
3
The distance between the rear edge of the first row and the front edge of the second row,
measured
from the side of the table
, is 56.4” (1432 mm).
4
The distance between the rear edge of the first row and the front edge of the second row,
measured
from the center of the table
, is 56.06” (1424 mm).
5
The minimum space between rear edge of the second row table and the rear wall is 44” (1120 mm).