2-12
Cisco TelePresence System TX9000 and TX9200 Assembly, Use & Care, and Field-Replaceable Unit Guide
OL-27038-01
Chapter 2 Room Requirements for the TX9000 and TX9200 Systems
Power Requirements For the TX9000 and TX9200
Peripherals such as document cameras or alternate displays will require additional power. Placement will
depend on the type and location of the peripheral device.
Number of Power Receptacles Required Per Room
Power receptacles required, excluding power in table legs—TX9000 and TX9200
4
Power receptacles required, including power in table legs—TX9000
5
Power receptacles required, including power in table legs—TX9200
7
1.
For systems that use South Africa lapton connections, change this number to 0.96 kW. For more information, see
2.
For systems that use South Africa laptop connections, change this number to 2.64 kW. For more information, see
Table 2-11
Summary of Power Requirements (continued)
Table 2-12
Power Requirements for System Components
Component
Number of
Units
Maximum
Per Unit in
Watts
Typical
Per Unit in
Watts
Standby/Idle
Per Unit in
Watts
Codec
4
129.60
99.60
72.00
Audio/Video extension unit
1
44.40
30.00
30.00
Light Control Unit (LCU)
1
1
1.
There are two power supplies for the LCU. Each power supply draws half this number.
216.0
216.0
27.6
Camera processor module
1
36
16.8
16.80
65-inch display
3
600.0
552.0
48.00/1.20
Presentation display
1
312.0
252.0
21.60/1.20
POWER TOTAL
for TX9000 and TX9200,
excluding power in table legs for conference
participants
2926.8 2569.2
528.0/367.2
Table 2-13
Power Requirements for Power in Table Legs for Conference Participants (Optional)
Component
Number of
Units
Maximum
Per Unit in
Watts
Typical
Per Unit in
Watts
Standby/Idle
Per Unit in
Watts
Participant Convenience Ports, front row
(6 participants)
6
1
1.
For systems that use South African power outlets (part number CTS-LAPCONN-SA, 74-1195-01), only one outlet per table
leg is allowed due to the size of the outlet. For these systems, change the convenience port number from 6 to 4 for the front
row, and from 12 to 7 for the second row. The power total changes from 1440 to 960 watts for six participants, and from
4320 to 2640 watts for 18 participants. The number of PDUs required is the same.
240
28.3
0.00
Participant Convenience Ports, second row
(12 participants)
12
240
28.3
0
POWER TOTAL
for 6 participants for
TX9000
1
1440
170
0
POWER TOTAL
for 18 participants for
TX9200
1
4320
510
0