Cisco TelePresence System TX9000 and TX9200 Assembly, Use & Care, and Field-Replaceable Unit Guide
OL-27038-01
Chapter 2 Room Requirements for the TX9000 and TX9200 Systems
Room Dimensions for the TX9000 and TX9200
Room Dimensions For the TX9200
For the TX9200, rectangular rooms are preferred, although irregular shaped rooms can also be
accommodated. The minimum and recommended room sizes for a Cisco TelePresence TX9200 system
are provided in
Note
These dimensions are for the full, 18-seat version of the TX9200. A 10- and 14-seat version is also
offered. For dimensions for these systems, see
Chapter 13, “Building the Second Row Table For a 14-
Note
Ceilings lower than 8’ (2.43 m) will not physically support the height of the CTS endpoint reflector wall.
The minimum room dimensions are illustrated in
. Only the differences between the TX9000
and the TX9200 are noted here; for additional dimensions including dimensions of the wall, see
.
Table 2-5
TX9200 Room Dimensions
Width
Depth
Height
Minimum
31’ (9450 mm)
21’ 5” (6530 mm) for
systems that use a
wall-mounted reflector
wall, 22’ 1” (6730 mm)
for systems that use a
free-standing reflector
wall
8’ (2440 mm)
Recommended
32’ 7” (9930 mm)
26’(7920 mm)
10’ (3050 mm)
Maximum
There is no defined maximum room size; this
number is dependent on echo and reverberation
factors that can be caused by larger rooms. Rooms
that are very wide may require acoustic wall
treatment. For more information, see the
Considerations For the TX9200” section on
page 2-21
.
Rooms with a height
greater than 10’ (3050
mm) may require
acoustic wall treatment.
For more information,
see the
Considerations For the
TX9200” section on
page 2-21
.