Chapter 2 Room Requirements for the TX9000 and TX9200 Systems
Room Dimensions for the TX9000 and TX9200
Room Dimensions for the TX9000 and TX9200
The following section includes the required room dimensions for your TX9000 and 9200 system and
includes the following topics:
•
Room Dimensions for the TX9000, page 2-4
•
Room Dimensions For the TX9200, page 2-6
Room Dimensions for the TX9000
For the TX9000, rectangular rooms are preferred although irregular shaped rooms can also be
accommodated. The minimum, recommended, and maximum room sizes for a TX9000 system are
provided in
Note
Ceilings lower than 8’ (2440 mm) will not physically support the height of the CTS endpoint reflector
wall.
The minimum room dimensions are illustrated in
:
Table 2-3
TX9000 Room Dimensions
Width
Depth
Height
Minimum
19’ (5800 mm)
14’4” (4370
mm)
1
1.
This measurement is for systems that have a wall-mounted reflector wall. For systems that have
a free-standing reflector wall, increase the minimum depth to 15’ (4570 mm).
8’ (2440 mm)
Recommended
21’(6400 mm)
18’ (5490 mm)
10’ (3050 mm)
Maximum
23’ (7010 mm)
31’ (9450 mm)
10’ (3050 mm)