75-39
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Chapter 75 Configuring Ethernet OAM and CFM
Enabling and Configuring Ethernet OAM
To configure Ethernet OAM link monitoring on an interface, perform this task:
Command
Purpose
Step 1
Switch#
configure terminal
Enters global configuration mode.
Step 2
Switch(config)#
interface
interface-id
Defines an interface, and enters interface configuration
mode.
Step 3
Switch(config-if)#
ethernet oam link-monitor
supported
Enables the interface to support link monitoring. it is the
default.
You need to enter this command only if it has been disabled
by previously entering the
no ethernet oam link-monitor
supported
command.
Step 4
Switch(config-if)#
ethernet oam link-monitor
symbol-period
{
threshold
{
high
{
high symbols
|
none
} |
low
{
low-symbols
}} |
window
symbols
}
Repeat this step to configure both high and low
thresholds.
(Optional) Configures high and low thresholds for an
error-symbol period that trigger an error-symbol period
link event.
•
Enter
threshold high
high-symbols
to set a high
threshold in number of symbols. The range is 1 to
65535. The default is
none
.
•
Enter
threshold
high none
to disable the high
threshold if it was set. it is the default.
•
Enter
threshold low
low-symbols
to set a low
threshold in number of symbols. The range is 0 to
65535. It must be lower than the high threshold.
•
Enter
window
symbols
to set the window size (in
number of symbols) of the polling period. The range is
1 to 65535 symbols.
Step 5
Switch(config-if)#
ethernet oam link-monitor
frame
{
threshold
{
high
{
high-frames
|
none
} |
low
{
low-frames
}} |
window
milliseconds
}
Repeat this step to configure both high and low
thresholds.
(Optional) Configures high and low thresholds for error
frames that trigger an error-frame link event.
•
Enter
threshold high
high-frames
to set a high
threshold in number of frames. The range is 1 to
65535. The default is
none
.
•
Enter
threshold
high none
to disable the high
threshold if it was set. it is the default.
•
Enter
threshold low
low-frames
to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
•
Enter
window
milliseconds
to set the a window and
period of time during which error frames are counted.
The range is 10 to 600 and represents the number of
milliseconds in multiples of 100. The default is 100.
Summary of Contents for Catalyst 4500 Series
Page 2: ......
Page 4: ......
Page 2086: ...Index IN 46 Software Configuration Guide Release IOS XE 3 9 0E and IOS 15 2 5 E ...