Section 5: Parts and Module Replacement
CP2210 Service Manual
5-13
020-100556-04 Rev. 1 (01-2012)
5.5.15 Lamp Replacement
Lamp replacement must be performed by Christie authorized service technicians only.
EXPLOSION HAZARD! Wear authorized Christie protective clothing (P/N: 598900-095)
whenever the lamp door is open and when handling the lamp. Never apply a twisting or
bending force to the quartz lamp body. Use the correct wattage lamp supplied by Christie.
Ensure those within the facility of the projector are also wearing protective safety clothing.
Never attempt to remove the lamp when it is hot. The lamp is under a great deal of
pressure when hot and may explode, causing personal injury or death, and/or property dam-
age. Allow the lamp to cool completely before handling.
NOTICE:
Improper installation of the lamp can cause serious damage to the projector.
(Estimated Replacement Time: 20 minutes; includes 5 minute LampLOC
™
alignment)
1. Press
Lamp OFF
from the TPC. Allow the cooling fans to run for at least 15 minutes to allow the lamp to
sufficiently cool before handling.
2. When the cooling fans stop turn the projector’s main switch to OFF and unplug. Always power down and
unplug the projector prior to servicing. Allow the lamp to cool before handling.
3. Wearing protective clothing and a face shield unlock the lamp door.
NOTE:
The safety interlock switch on
the lamp door turns lamp power OFF and prevents it from being turned ON when the door is open. The
interlock wiring connects directly to the LPS.
NOTICE:
DO NOT place heavy objects on the open rear
access door.
4. Manually turn the two thumbscrews on the internal lamp door counter-clockwise to access the lamp
compartment.
5. Using a 5mm hex key, loosen the nut securing the anode wire (
Figure 5-16/D
).
A
Reflector
B
Anode Wire
C
Captive Screws
D
Anode Nut
E
Cathode Screw
F
Cathode Nut
G
Cathode Clamp
H
Cathode Wire
Figure 5-16 Lamp Assembly