Section 5: Parts and Module Replacement
CP2210 Service Manual
5-35
020-100556-04 Rev. 1 (01-2012)
110V AC Line Filter
UV HAZARD!
Always wear protective safety clothing and a face shield when performing
service with the safety shield removed and a lamp installed.
1. Disconnect the AC power cord.
2. Unlock the rear access door.
3. Remove the top lid. Refer to
5.5.5 Top Lid, on page 5-7
.
4. Remove the safety shield. Refer to
5.5.12 Safety Shield, on page 5-10
.
5. Open the lamp door. Refer to
5.5.10 Lamp Door, on page 5-9
.
6. Remove the two M5 screws securing the AC line filter on the inside of the projector housing.
(
Figure 5-50
)
7. Remove the two M3 screws securing the AC line filter on the outside of the projector housing.
(
Figure 5-50
)
Figure 5-50 Remove AC Line Filter
8. Disconnect the two harnesses from the 110V AC line filter. (
Figure 5-49, B
)
9. Use a #1 Phillips
™
to remove the two screws securing the AC line filter to the rear skin frame.
10. Reverse the above steps to install the 110V AC line filter.
220V AC Line Filter
UV HAZARD!
Always wear protective safety clothing and a face shield when performing
service with the safety shield removed and a lamp installed.
1. Disconnect the AC power cord.
2. Unlock the rear access door.
3. Remove the top lid. Refer to
5.5.5 Top Lid, on page 5-7
.
4. Remove the safety shield. Refer to
5.5.12 Safety Shield, on page 5-10
.
5. Open the lamp door. Refer to
5.5.10 Lamp Door, on page 5-9
.