Section 5: Parts and Module Replacement
CP2210 Service Manual
5-15
020-100556-04 Rev. 1 (01-2012)
5.5.16 Lens
(Estimated Replacement Time: 2 m 2 minutes for calibration)
1. Remove the two hex screws from the mounts.
2. Position the lens clamp OPEN to unlock the lens
from the mount.(
Figure 5-18
)
3. Pull the lens out of the lens mount.
5.5.17 Lens Flags
1. Remove the lens. Refer to
5.5.16 Lens, on page 5-
15
.
2. Use a #1 Phillips
™
screwdriver to remove the two
M2 x 4mm screws and lock washers securing the
lens flag to the lens.
3. Position the replacement flag (P/N: 012-101504-
xx) so it is centered between the two mounting
positions. (
Figure 5-19
)
4. Use a #1 Phillips
™
screwdriver to install the
supplied M2 x 4mm screws (P/N: 012-100031-xx)
to secure the flag to the lens.
5. Manually rotate the lens to ensure there is no interference. If the lens does not rotate easily the lens itself or
the motors may be damaged.
6. Reinstall the lens. For details, refer
5.5.16 Lens, on page 5-15
.
7. Perform lens calibration using either the TPC. For details, refer to the
CP2210 User Manual (P/N: 020-
100410-xx)
.
NOTES: 1)
All lens types use the same lens flag for both zoom and focus (P/N: 021-101504-xx).
2)
All lenses
have a zoom and focus lens flag, except for the 1.05:1 lens, which only has one flag for focus.
Figure 5-19 Replacing Lens Flags
Figure 5-18 Remove Lens